FireSafe PlusThe system has a classification of E120 EW120 in accordance with BS EN 13501- 2:2007+A1:2009
|
FireSafe 240The system has a classification of E240 EW30 C0 Sa in accordance with BS EN 13501-2:2007+A1:2009.
|
ResQ-WindowThe system has a classification of E120 EW30 C0 in accordance with BS EN 13501-2:2007+A1:2009.
|
SmokeSafe D120CE Marked according to BS EN 12101- 1:2005+A1:2006 Annex ZA with
its AVCP by Warrington Certification Ltd. |
FireSafe PLUS provides the highest safety level of fire protection allowing a total gravity fail safe passage of escape both through and close by to the fire barrier. FireSafe PLUS is designed for all application types where a higher performance of radiation is required i.e. protecting a means of escape.
FireSafe Plus system remains hidden until required. Upon receiving a signal from the fire detection system or on loss of power the Operable Fire Barrier unwinds to its fire operational position under a gravity-controlled descent. |
Curtain Drop |
Single Box Standard Size (WxH) |
Up to 2.5m |
180x180mm |
2.5m to 4m |
200x200mm |
4m to 6.6m |
210x240mm |
The FireSafe 240 is an electrically operated Automatic Fire Barrier, to be used to form a barrier against fire.
FireSafe 240 system can be provided to opening widths of up to 30m and heights up to 6m utilising a multiple roller configuration. |
Curtain Drop |
Single Box Standard Size (WxH) |
Double Box Over/Under Size (WxH) |
Up to 2.5m |
180x180mm |
160x320mm |
2.5m to 4m |
200x200mm |
180x360mm |
4m to 6.6m |
210x240mm |
200x400mm |
ResQ-Window is designed for doorways, corridors, lift shafts, areas of refuge and other areas where people and emergency services may need access.
The two transparent windows in the ResQ-Window Automatic Fire Barrier are positioned to allow a low and high-level ‘Safe View’ through the panels. Firefighters will be able to see if there are survivors behind an Automatic Fire Barrier through the clear vision ‘Safe View’ panel to immediately assist their dynamic decision process. |
Curtain Drop |
Single Box Standard Size (WxH) |
Double Box Over/Under Size (WxH) |
Up to 2.5m |
180x180mm |
160x320mm |
2.5m to 4m |
200x200mm |
180x360mm |
4m to 6.6m |
210x240mm |
200x400mm |
The CE Marked SmokeSafe system is a smoke barrier without side guides and provides up to 120 minutes of smoke and heat protection. It is the most discreet operable fabric barrier available; designed to be installed in commercial properties such as shopping centres and airports, and channel smoke to a (SHEVS) Smoke Heat Exhaust Ventilation System.
|
Curtain Drop |
Single Box Standard Size (WxH) |
Double Box Over/Under Size (WxH) |
Up to 2.5m |
180x180mm |
160x320mm |
2.5m to 4m |
200x200mm |
180x360mm |
4m to 6.6m |
210x240mm |
200x400mm |